Figure 5

Check Low Bias Pressure:

 Pull one of the two blue wires going into the modulating valve. (This simulates a temperature

drop and allows the oven to run at Low Flame Bias)


If the flame goes out turn the 5mm screw clockwise 1 turn to increase Low Flame
Bias

 Wait 30 seconds and the oven will re-light.
 Using a 5mm socket turn the Low Flame Bias screw (Figure 6) until desired setting is

achieved. Use (Figure 5) for correct valve settings.

Figure 6

OVEN SERVICE PROCEDURES

Multi-Valve Adjustment Procedure

NOTE

5 mm

W/C

mbar

kPa

W/C

mbar

kPa

3.5

8.75

0.875

10

25

2.5

0.1

0.25

0.025

0.1

0.25

0.025

Multi-Valve Adjustment Settings

All Oven Models

Natural Gas

LP Gas

Low Flame Bias

High Flame Bias

Advertising