5.7.7 UPS Enable/Disable
Jumper Label:
JP3
Jumper Type:
2-pin header
Jumper Settings:
See Table 5-8
Jumper Location:
See Figure 5-4
When this jumper is closed, the system will use the battery when needed, when open the
system will not use the battery.
Pin Setting
Description
Open
Don't use the battery backup
Closed
Use the battery function
Table 5-8: UPS Enable/Disable Jumper Settings
5.7.8 UPS/Battery Mode Selection
Jumper Label:
J_U/B1
Jumper Type:
3-pin header
Jumper Settings:
See Table 5-9
Jumper Location:
See Figure 5-4
This jumper sets the system to run off the battery exclusively, or to use the battery as a
UPS.
Pin Setting
Description
1-2
UPS
2-3
Battery