Chapter 1

31

Installing the 82357A

Step 6: Programming via the 82357A

Accessing VISA and

SICL Manuals

You can access .pdf copies of the Agilent VISA User’s Guide and the
Agilent SICL User’s Guide for Windows

from the blue IO icon on the

Windows taskbar. Adobe Reader is required to view these manuals.

To access the Agilent VISA User’s Guide, click the IO icon and then click

Documentation | VISA Users Guide

. To access the Agilent SICL User’s Guide

for Windows

, click the IO icon and then click

Documentation | SICL Users

Guide

. To access VISA COM information, and function references for VISA,

VISA COM, and SICL, click the IO icon and then click

Documentation | IO

Libraries Suite Help.

Introduction to IO

Interface

Configuration

An

IO interface

consists of a hardware interface and a software interface.

One purpose of the Connection Expert utility is to associate a unique
software interface ID with a hardware interface.

The Agilent IO Libraries Suite uses an

Interface ID

or

Logical Unit Number

to

identify an interface. This information is passed in the parameter string of
the

viOpen

function call in a VISA program or in the

iopen

function call in

a SICL program.

Connection Expert assigns an Interface ID and Logical Unit (LU) Number to
the interface hardware, as well as other necessary configuration values for
an interface when the interface is configured. Typically, the LU Number is
automatically assigned and you can ignore its setting. The LU Number is
used internally as a unique identifier. When the IO interface is configured,
you can use Agilent VISA, VISA COM, or SICL to program assigned
instruments.

Example: IO

Interface

Configuration

For example, the GPIB interface system in the following figure consists of
a Windows PC with an 82357A USB/GPIB Interface Converter connected
between a USB port and three GPIB instruments with GPIB primary
addresses of 3, 4, and 5, respectively. The instruments are connected via
GPIB cables.

For this system, the Connection Expert utility has been used to assign a
VISA name of “GPIB1” and a SICL name of “hpib7”. With these names
assigned to the interfaces, the VISA/SICL addressing is as shown in the
figure.

Since unique names have been assigned by Connection Expert, you can
use the VISA viOpen command to open the IO paths to the GPIB

instruments as shown in the figure. Or, you can use the SICL iopen

command to open the IO paths.