TROUBLESHOOTING

E-4

COOL ARC

®

55 S

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Cooler does not operate.
Error 92 on cooler.(See below)

Internal water leak.

Torch or gun runs hot.

Fan operates but there is low coolant
flow.

Fan operates but there is no coolant
flow.

Pump operates, but fan does not.
Cooler trips outlet circuit breaker.

Cooler trips outlet circuit breaker.

Error 92.

1. Input cord unplugged.
2. Power harness damaged.
3. Water lines blocked, crimped or

disconnected.

4. Leak in gun or water hoses.
5. Coolant reservoir empty.
6. The system needs to be primed.

1. Hose clamp loose on one of inter-

nal hoses.

2. Internal hose punctured.
3. Heat exchanger leaking.
4. Pump seal is leaking.

1. Unit placed by area of extreme

heat.

2. Low coolant flow.
3. No coolant flow. (Arclink cable

unplugged).

4. Fan not operating.
5. Heat exchanger clogged.

1. Leak in torch/gun or hoses.
2.Torch/gun or hoses partially

obstructed.

3. Reservoir empty or very low.
4. Pump strainer is dirty.

1. Pump or pump motor failure.
2. Pump strainer is blocked.

1. Loose or disconnected fan lead.
2. Obstruction in fan blade.
3. Fan motor failure.

1. Circuit overloaded.
2. Fan or pump motor failure.

1. Flow switch not closing within sev-

eral seconds of welding.

2. Make sure hoses are properly

connected and coolant is returning
to the cooler.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.