Installation – Lincoln Electric IM10098 CRUISER User Manual

Page 19

Advertising
background image

A-12

INSTALLATION

CRUISER

A-12

CABLE CONNECTIONS

WELD CABLE SIZES

Tabulated below are copper cable sizes recommended
for different currents and duty cycles. Lengths stipulat-
ed are the distance from the welder to work and back
to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable drop.

** Tabled values are for operation at ambient temperatures of 40°C and below. Applications above 40°C may

require cables larger than recommended, or cables rated higher than 75°C.

FIGURE A.20 - WIRE DRIVE MOUNTING

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK
CABLES

Amperes

Percent

Duty
Cycle

0 to 50 Ft.

50 to 100 Ft.

100 to 150 Ft.

150 to 200 Ft.

200 to 250 Ft.

600
600
600
650
650
700

60
80

100

60
80

100

3/0

2-1/0
2-1/0

3/0

2-1/0
2-2/0

3/0

2-1/0
2-1/0

3/0

2-1/0
2-2/0

3/0

2-1/0
2-1/0

4/0

2-1/0
2-3/0

4/0

2-2/0
2-2/0
2-2/0
2-2/0
2-3/0

2-3/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0

800
800

1000

80

100

80

3-1/0
2-3/0
2-4/0

3-1/0
2-3/0
2-4/0

3-1/0
2-3/0
2-4/0

2-3/0
2-3/0
2-4/0

2-4/0
2-4/0
4-2/0

1000
1200
1200
1500
1500

100

80

100

80

100

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0