Installation, Technical specifications - idealarc, Ac-1200 – Lincoln Electric IM10119 IDEALARC AC-1200 User Manual
Page 8

A-1
INSTALLATION
IDEALARC
®
AC-1200
A-1
Weight
1636 lbs.
(742 kg.)
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
PHYSICAL DIMENSIONS
RECOMMENDED INPUT WIRE GROUNDING CONDUCTOR AND FUSE SIZES
Standard Voltage
Duty Cycle
100%
Current Range
240/1200
Maximum Open Circuit Voltage
Depth
38.00 in.
(965.2mm.)
Width
22.30 in.
(566.4mm.)
Height
53.50 in.
( 1358.9mm.)
AMPS AC
1200 @ 44 Volts
Input Current at 100% Rated Output
Single Phase Output
Scott Connection
460/60
440/50/60
415/50/60
380/50/60
182
209
190
219
201
232
220
255
TECHNICAL SPECIFICATIONS - IDEALARC
®
AC-1200
86-88
RATING: IP21 ENCLOSURE
Power Factor @ Rated load With P.F. Capacitors
79%(60 Hz)
76%(50 Hz)
Input Copper Wire Size - 75˚C in Conduit Super Lag Fuses
Voltage/ Input Amps Power Input Wires Grounding Conductor Size in Amps
Hertz
1 Phase Scott
1 Phase
Scott
1 Phase
Scott
1 Phase Scott
Conn.
Conn.
Conn.
Conn.
460/60
182
209
#4/0
250MCM
#4
#3
300
350
440/50/60
190
219
#4/0
250MCM
#4
#3
300
350
415/50/60
201
232
#4/0
300MCM
#4
#3
300
350
380/50/60
220
255
250MCM
350MCM
#3
#3
300
400