TROUBLESHOOTING

E-3

GX 300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine will not idle down to low
speed.

Engine will not go to high idle when
attempting to weld.

Engine will not go to high idle when
using auxiliary power.

Engine does not develop full
power.

1. Idler switch in High idle position.

Set switch to Auto.

2. External load on welder or auxil-

iary power. Remove all external
loads.

3. Faulty PC board or idler sole-

noid.

1. Poor work lead connection to

work. Make sure work clamp is
tightly connected to clean base
metal.

2. "Contactor" switch is in wrong

position. Set to "Welding On" when
welding without a control cable.
Refer to Operations chapter for prop-
er use of this switch.

3. Faulty PC board. Low idle speed

set to low.

1. Auxiliary power load is less than

100 watts. Idler may not respond
with less than a 100 watt load. Set
idler to "High".

2. Faulty PC board.

1. Fuel filter clogged, Replace.
2. Air filter clogged, clean or replace.
3. Fouled spark plugs, clean or

replace.

4. Valves out of adjustment.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Authorized
Field Service Facility.