Installation, Select suitable location, Safety precautions – Lincoln Electric IMT10099 POWER MIG 140_180 User Manual

Page 10: Warning

Advertising
background image

INSTALLATION

POWER MIG® (140, 180 MODELS)

A-2

A-2

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can
block air passages and cause overheating.

STACKING

POWER MIG® (140, 180 MODELS) cannot be
stacked.

TILTING

Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.

Read entire installation section before starting
installation.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Only qualified personnel should perform

this installation.

• Only personnel that have read and under-

stood the POWER MIG Operating Manual
should install and operate this equipment.

• Machine must be plugged into a receptacle

which is grounded per any national, local
or other applicable electrical codes.

• The POWER MIG power switch is to be in

the OFF (“O”) position when installing
work cable and gun and when connecting
power cord to input power.

WARNING

Advertising