Installation – Lincoln Electric IMt10100 WIRE FEEDER WELDER 140_180 User Manual

Page 7

Advertising
background image

A-1

A-1

INSTALLATION

WIRE FEEDER WELDERS (140, 180 MODELS)

TECHNICAL SPECIFICATIONS 180 Amp units (K2689-2)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Standard Voltage/Frequency

Input Current

230 V 60 Hz

20 Amps @ rated output

208 V 60 Hz

20 Amps @ rated output

Voltage/Duty Cycle

Current

Voltage at Rated Amperes

230 V 30%

130 Amps

20

208 V 30%

130 Amps

17

Welding Current Range

Open Circuit Voltage

Wire Speed Range

30-180 Amps

34 V

50 - 500 in/min.

(1.3 - 12.7 m/min.)

Input Voltage/Frequency Fuse or Breaker Size

1

Input Amps Power Cord

230 V 60 Hz

40 Amp Super Lag

20 50 Amp, 250 V,

Three Prong Plug

(NEMA Type 6-50P)

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

13.7 in

10.15 in

17.9 in

64 Ibs

347 mm

258 mm

454 mm

29 kg

PHYSICAL DIMENSIONS

1

If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.

OPERA

T

ORʼS MANUAL

140 Amp units (K2688-2)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Standard Voltage/Frequency

Input Current

120 V / 60 Hz

20 Amps @ rated output

Duty Cycle

Current

Voltage at Rated Amperes

20% Duty Cycle

90 Amps

19.5

Welding Current Range

Open Circuit Voltage

Wire Speed Range

30-140 Amps

33 V

50 - 500 in/min.

(1.3 - 12.7 m/min.)

Input Voltage/Frequency Fuse or Breaker Size

1,2

Input Amps

Power Cord Extension Cord

120 V 60 Hz 20 Amp

20

15 Amp, 125 V, 3 Conductor # 12 AWG

Three Prong Plug (4mm

2

) or Larger

(NEMA Type 5-15P) up to 50 ft.(15.2m)

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

13.7 in

10.15 in

17.9 in

54 Ibs

347 mm

258 mm

454 mm

24.5 kg

PHYSICAL DIMENSIONS

1

If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.

Advertising