G7200 – NOCO Genius G7200 User Manual

Page 9

Advertising
background image

15

14

G7200

geniuschargers.com

USING THE G7200

USING 13.6V SUPPLY MODE

The 13.6V SUPPLY mode is used for low voltage batteries, maintenance
charging or as a power supply for 12V batteries (14-230Ah).

In order to operate the 13.6V SUPPLY mode, the battery charger

MUST NOT

be connected to the battery.

CAUTION. USE THIS MODE WITH CARE. BOTH THE SPARK PROOF AND
REVERSE POLARITY SAFETY FEATURES ARE DISABLED. PAY CLOSE
ATTENTION TO THE POLARITY. DO NOT ALLOW THE POSITIVE AND
NEGATIVE BATTERY CLAMP OR EYELET TERMINAL CONNECTORS TO
TOUCH OR CONNECT TO EACH OTHER AS THE BATTERY CHARGER
COULD GENERATE SPARKS. CHECK THE POLARITY OF THE BATTERY
TERMINALS BEFORE USING THIS MODE.

To operate the 13.6V SUPPLY mode, follow these steps:
1.)
Confirm that the AC power plug is plugged into an electrical outlet, the
battery charger is NOT CONNECTED TO THE BATTERY and you have a 12V
battery.

THIS MODE IS FOR 12V BATTERIES ONLY.

2.) Check the polarity of the battery terminals. Make sure you understand
which battery terminal is POSITIVE and which one is NEGATIVE.
3.) Without a battery attached, PRESS and HOLD the MODE button for three
(3) seconds until the Red LED illuminates, indicating the 13.6V SUPPLY mode
is initiated.
4.) PAYING CLOSE ATTENTION TO THE POLARITY (POSITIVE TO POSITIVE,
NEGATIVE TO NEGATIVE) attach the battery clamps or eyelet terminal
connectors to the battery, starting with the POSITIVE cable first (NEGATIVE
first, if a Positive Ground System).
5.) When finished, PRESS the MODE button one (1) time to exit the 13.6V
SUPPLY mode and return the battery charger to STANDBY mode.

WICKED SMART TIP

After using this mode for low voltage batteries, if the battery voltage is
still below 7.0VDC, repeat the steps above and try leaving the battery
charger in 13.6V SUPPLY for a longer period of time. If after twenty-four
(24) hours the battery voltage is still below 7.0VDC, you may have a
battery in poor condition.

Now That’s Smart, Wicked Smart.™

USING THE G7200

USING 16V BOOST MODE

The 16V BOOST mode is used to recover battery capacity from a stratified
(sulfated) 12V battery (14-230Ah).

In order to operate the 16V BOOST mode, the battery charger

MUST be

connected to the battery.

CAUTION. USE THIS MODE WITH CARE. THIS MODE USES A HIGH
VOLTAGE AND MAY CAUSE SOME WATER LOSS IN WET (FLOODED) CELL
BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS MAY
BE SENSITIVE TO HIGH CHARGING VOLTAGES. FOR OPTIMAL RESULTS,
TAKE THE BATTERY THROUGH A FULL CHARGE CYCLE, BRINGING THE
BATTERY TO FULL CHARGE, BEFORE USING THIS MODE. TO MINIMIZE
RISKS TO ELECTRONICS, DISCONNECT THE BATTERY BEFORE USING
THIS MODE.

To operate the 16V BOOST mode, follow these steps:
1.)
Confirm you have a 12V battery. THIS MODE IS FOR 12V BATTERIES
ONLY.
2.)
Attach the battery clamps or eyelet terminal connectors to the battery,
starting with the POSITIVE cable first (NEGATIVE first, if a Positive Ground
System). If you have accidentally reversed the polarity, an ERROR LED
(Orange) will illuminate. The battery charger has an internal safety feature to
protect the battery charger from damage if this situation should occur. Reverse
the connections to clear the ERROR LED and proceed to the next step.
3.) Connect the battery charger’s AC power plug into a suitable electrical
outlet. DO NOT FACE THE BATTERY WHEN MAKING THIS CONNECTION.
4.) With a battery attached, PRESS and HOLD the MODE button for three (3)
seconds until the Red LED illuminates, indicating the 16V BOOST mode is
selected. After five (5) seconds, the Red LED will begin blinking indicating the
16V BOOST mode has been initiated.
5.) When finished, PRESS the MODE button one (1) time to exit the 16V
BOOST mode and return the battery charger to STANDBY mode.