BATTERY SPECS

The following recommendations should ONLY be considered as guidelines.
Always refer to the battery manufacturer’s recommendations for battery
charging. The G26000 is suitable for charging all types of 12V & 24V lead-
acid batteries, including Wet (Flooded), Gel, MF (Maintenance-Free) and AGM
(Absorption Glass Mat) batteries. The G26000 can be used on battery sizes
from 50 to 500Ah (12V), 25-250Ah (24V) and 25-100Ah (12V Calcium). The
battery charger can also maintain all sizes of 12V & 24V batteries.

CHARGE MODES

The G26000 is equipped with ten (10) charging modes, 12V NORM,
12V COLD/ AGM, 24V NORM, 24V COLD/AGM, 13.6V SUPPLY, 13.6V
EQUALIZATION, 16V BOOST, 32V BOOST, SILENT NIGHT and 12V CALCIUM.
Before selecting a charge mode, it is important to understand the differences
and the purpose of each mode. The charge modes are explained below:

The “normal” (“NORM”) charge mode is for charging
12V Wet Cell, Maintenance-Free and Gel Cell
batteries. If you are unsure of the chemistry of your
battery, use the NORM charge mode. When selected,
a Red LED will illuminate.

The COLD/AGM charge mode is for charging 12V
batteries in cold weather and AGM (also known as
“spiral wound”) batteries. If a battery’s (Wet, Gel, MF
or AGM) temperature is below 32

o

F (0

o

C), use the

COLD/AGM charge mode. If you are unsure of the
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.

12V NORM
14.4V
50-500Ah
26A (26000mA)
Red LED

12V COLD/
AGM
14.7V
50-500Ah
26A (26000mA)
Blue LED

USING THE G26000

MODE EXPLANATION

The “normal” (“NORM”) charge mode is for charging
24V Wet Cell, Maintenance-Free and Gel Cell
batteries. If you are unsure of the chemistry of your
battery, use the NORM charge mode. When selected,
a Red LED will illuminate.

The COLD/AGM charge mode is for charging 24V
batteries in cold weather and AGM (also known as
“spiral wound”) batteries. If a battery’s (Wet, Gel, MF
or AGM) temperature is below 32

o

F (0

o

C), use the

COLD/AGM charge mode. If you are unsure of the
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.

The 13.6V EQUALIZATION mode is used to provide
an equalization charge by delivering a constant
voltage of 13.6V. Individual battery cells can
react differently to charging. Over time, battery
performance can decline as the differences become
more severe. Equalization is a method of increasing
battery life and should be performed at least once a
month.

FOR USE WITH 12V BATTERIES ONLY.

In SILENT NIGHT mode the battery chargers internal
cooling fan disabled for quiet operation. When using
this mode, the charge current is reduced to 5A.

FOR USE WITH 12V BATTERIES ONLY.

24V NORM
28.8V
25-250Ah
13A (13000mA)
Red LED

24V COLD/AGM
29.4V
25-250Ah
13A (13000mA)
Blue LED

13.6V
EQUALIZATION
13.6V
14-230Ah
5A (5000mA)
Red LED

SILENT NIGHT
14.4V
14-230Ah
5A (5000mA)
Red LED

USING THE G26000

MODE EXPLANATION

CHARGE MODES continued

Continued On Next Page