STARTING THE ENGINE

Disconnect all electrical loads from the unit.

1. Check oil level and fuel connections.

2. Open the cylinder fuel valve (A) SLOWLY to allow fuel

to flow to the generator.

3. Adjust choke (B) as necessary.

NOTE: For cold engine starting only, slide the choke

lever to the full choke position.

4. Turn the engine ON/OFF switch (C) to the “ON”

position.

5. Press down on the “Press to Prime” button for 2 seconds

to allow gas to flow.

6. Pull the recoil (D) slowly until resistance is felt, then

rapidly crank twice for gas to fill carburetor.

7. Set the choke lever to the RUN position.

8. Start the engine by pulling the recoil (D) slowly until

resistance is felt, then pull rapidly to crank the engine.

Repeat if necessary.

NOTE: If the engine fails to start, press the Primer

button again and repeat the starting instructions.

9. Plug in electrical loads.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full

capacity. Before starting the generator, disconnect all load.

Apply load only after generator is running. Voltage is

regulated via the engine speed adjusted at the factory for correct

output. Readjusting will void warranty.

STOPPING THE GENERATOR
1. Before stopping the engine, make sure all electrical loads

are unplugged from the panel.

2. Let the engine run for two minutes without load.
3. Turn the engine ON/OFF switch to the “OFF” position.
4. Do not leave the generator until it has completely

stopped.

5. Turn off the Propane cylinder fuel valve.
6. If a cover is used, do not install until unit has cooled.
7. If the generator will not be used again for an extended

time period, refer to the SERVICE AND STORAGE

section of this manual.

15

Customer Hotline 1-800-445-1805

Provide adequate ventilation for toxic exhaust gases and

cooling air flow.

Do not start or run the generator in an enclosed area,

even if door or windows are open.

Engines give off carbon monoxide, an odorless, colorless,

poison gas.

Breathing carbon monoxide can cause nausea, fainting or

death.

When applying a load, do not exceed the maximum wattage

rating of the generator when using one or more receptacles.

Also, do not exceed the amperage rating of any one

receptacle.

Do not apply heavy electrical load during break-in period (the

first two to three hours of operations).

English

Allow generator to run at no load for two minutes upon each

initial start-up to permit engine and generator to stabilize.

D

A

START RUN

C

B

PRESS TO PRIME