Installation – Powermate PM0133250 User Manual

Page 6

Advertising
background image

6

Customer Hotline 1-800-445-1805

To avoid backfeeding into utility systems, isolation of the

residence electrical system is required.

Before temporary connection of the generator to the

residence electrical system, turn off the main

service/disconnect.

If your generator is to be used as a stand-by power source

in case of utility power failure, it should be installed by a

registered electrician and in compliance with all applicable

local electrical codes.

Proper use requires that a double throw transfer switch be

installed by a licensed qualified electrician so that the

building's electrical circuits may be safely switched between

utility power and the generator's output, thereby preventing

backfeed into the power utility's electrical system.

Always follow local codes and regulations that apply to

the installation of any item that concerns this product.

1. NFPA 70 - National Electrical Code available from

www.nfpa.org.

2. NFPA 37 - Standard for Installation and Use of

Stationary Combustible Engines available from

www.nfpa.org.

3. NFPA 5000 - Building Construction and Safety Code

available from www.nfpa.org.

4. Agricultural Wiring Handbook available from

www.rerc.org.

English

To avoid backfeeding into utility systems, isolation of

the residence electrical system is required. Before

temporary connection of a generator to the residence

electrical system turn off the main switch. Before

making permanent connections a double throw

transfer switch must be installed. To avoid

electrocution or property damage, only a trained

electrician should connect generator to residence

electrical system. California law requires isolation of

the residence electrical system before connecting a

generator to residence electrical systems. Temporary

connection not recommended due to backfeeding.

INSTALLATION

INSTALLATION

To avoid possible personal injury or equipment

damage, a registered electrician or an authorized

service representative should perform installation and

all service. Under no circumstances should an

unqualified person attempt to wire into a utility

circuit.

Advertising