Powermate PM0148000 User Manual

Page 7

Advertising
background image

7

Customer Hotline 1-800-445-1805

A. Control Panel

NOTE: Total power drawn from all receptacles must not exceed

the nameplate ratings.

B. 120 V, 20 Ampere Receptacle

20 amps of current may be drawn from the receptacle.

However, total power drawn must be kept within nameplate

ratings.

C. 120 Volt, 30 Ampere Twistlock Receptacle

You may draw a maximum of 30 amps from this

receptacle. If other receptacles are used at the same time,

total power used must be kept within nameplate ratings.

D. 120/240 V, 30 Ampere Twistlock Receptacle

Maximum full load current may be drawn from the

120/240 volt receptacle. Total current must be limited to

the nameplate rating. If the 120/240 volt receptacle is used

along with the 120 volt receptacle, the total load drawn

must not exceed the nameplate ratings.

E. Circuit Protectors

The receptacles are protected by an AC circuit protector. If the

generator is overloaded or an external short circuit occurs, the circuit

protector will trip. If this occurs,

disconnect all electrical loads and try to determine the cause

of the problem before attempting to use the generator again. If

overloading causes the circuit protector to trip, reduce the

load. NOTE: Continuous tripping of the circuit protector may

cause damage to generator or equipment. The circuit protector

may be reset by pushing the button of the protector.

F. Ground Terminal

G. Air Filter

H. Engine On/Off/Start Switch

I. 445 CC OHV Engine

J. Recoil Starter

K. Engine Choke Lever

L. Oil Filler Cap

M. Oil Drain Plug

N. 7 Gallon Metal Fuel Tank

O. Fuel Tank Cap

P. Fuel Gauge

Q. Fuel Shut-Off Valve

R. Multimeter

When the generator is started, the voltage value is shown first.

Press and release the mode button to toggle between Voltage,

Frequency, Total Hour Meter and Run/Maintenance

Timer.

• Voltage (V) displays the operating voltage of the generator.

• Frequency (F) displays the frequency in hertz at which the

generator is running.

The Run/Maintenance Timer displays the time in hours and

minutes each time the generator is ran. The run timer resets

to 00:00 when the generator is shut off. Built into this run

timer is a maintenance reminder. When the new generator is

ran for 25 hours, the meter will display P25. This is to

remind you to change the oil after the initial 25 hours of run

time.

• When the Run/Maintenance Timer displays P50, it is

reminding you to clean the air filter.

When the Run/Maintenance Timer displays P100, it is

reminding you to change/clean the fuel filter, clean the air

filter, and change the oil.

A

B

Q

E

J

L

M

H

K

O

C

D

F

E

R

N

I

P

English

G

GENERATOR FEATURES

GENERATOR FEATURES