Pumptec Operating Instructions and Parts Manual

UPGRADE KITS

uNPAcKINg

Remove all packing materials. Carefully remove the upgrade

kit from the shipping carton. Inspect for any damage that may

have occurred during transit. Check for any loose, missing or

damaged parts. See individual kits in the parts list section.

The contents include:

1. Dayton upgrade kit parts.

2. Pump/Motor assembly.

Refer to pages 8-12 for lists of parts.

gEnEraL SaFEty inFormation

Please read this manual before installing or operating pump

to provide safe operation and prevent equipment problems.

Observe the following symbols and definitions.

Note:

Indicates important instructions which are not related

to hazards.

IMPortANt:

Indicates factors concerned with assembly,

installation, operation, or maintenance which could result in

damage to the machine or equipment if ignored.

cAutIoN!

Warns about hazards that MAY cause

minor personal injury or property damage if ignored.

WArNINg!

Warns about hazards that COULD cause

serious personal injury, death or major property damage if

ignored.

DangEr!

Warns about hazards that WILL cause

serious person injury, death or major property damage if

ignored.

___________________________________________

PLEaSE rEaD, SavE anD rEFEr to SaFEty

inStruCtionS bELow:

cAutIoN!

Pumps build up heat and pressure during

operation. Allow time for pumps to cool before handling or

servicing. Only qualified personnel should install, operate, and

repair pump.

IMPortANt:

For pumping liquids other than water, contact

your supplier.

DangEr!

Do not pump hazardous materials

(flammable, caustic, etc.), unless the pump is specifically

designed and designated to handle them.

WArNINg!

To reduce risk of electric shock, always

disconnect pump from power source before handling or

servicing.

WArNINg!

Any wiring of pumps should be performed

by a qualified electrician.

cAutIoN!

These pumps are not intended to be

submersed.

Pumptec, Inc. is not responsible for losses, injury, or death

resulting from a failure to observe these safety precautions,

misuse or abuse of pumps or equipment.

aSSEmbLy oF uPgraDE kit

Refer to Pages 8-12 for unit specific assembly.

Below is a basic system diagram for assembly reference.

1. Attach elbows to each side of “outs” on pump.

2. Attach black pulse hose to left elbow.

3. Attach black plug to left “in”.

4. Attach regulator to right elbow.

5. Place 3/8” clamps to each end of 3/8” poly spring hose.

Attach 3/8” hose to regulator and tighten clamp.

6. Place 1/2” clamps to each end of 1/2” hose. Attach 1/2” hose

to right side pump inlet.

inStaLLation oF uPgraDE kitS

The pumping system can be mounted where it is visible, but

it must be protected from rain, dirt and chemical spray or

splashing. The pump must never be installed on a vertical

surface with the pump head higher than motor; for example:

like a capital letter “T”.

Advertising