Installation and Use

Guar

d

ian F

al

l Pr

o

tection

6305 S. 231s

t St

., K

e

nt

, W

A

98032

phone: (800) 466

-6385 f

ax

: (800) 670

-7892

www

.guar

d

ianf

al

l.c

o

m

11

ALWAYS follow all instructions of all equipment used

in combination with the Construction Tux Harness.

ALWAYS ensure all product-specific application specifications are met and adhered to.

NEVER attach connector to any place on harness other than D-ring.

Connector gate must be self-closing and self-locking, and must

withstand minimum load of 3,600 lbs.

ALL PFAS equipment must be selected and deemed compatible with

the Construction Tux Harness by a Competent Person.

To connect Pass-Through Buckle, angle male buckle so it
is positioned to pass up and through female buckle.
Fully insert male buckle so that it lies flat on top of
female buckle.

To connect Tongue Buckle, pull webbing strap through
framed tongue component, and insert framed tongue
through grommet to secure.

Dorsal D-ring, chest strap, shoulder straps, and leg straps

MUST be fitted for each individual user.

To adjust dorsal D-ring, slide placard up or down webbing.
Dorsal D-ring must rest between the middle of the
shoulder blades.

Roller and Friction Adjustments allow the user to make
adjustments to Velocity Harness straps. Feed webbing through
buckle, and slide the buckle down on the strap to tighten, or
slide the buckle up on the strap to loosen.