PROFESSIONAL DUTY • FIXED PITCH ROOFING BRACKETS

60˚

45˚

90˚

INSTRUCTIONS FOR INSTALLA-

TION AND USE OF THE MODEL

#3503 8”x 60 DEGREE FIXED

PITCH ROOFING BRACKET

(FOR USE ON 21/12 PITCH

ROOFS): CAPACITY: One worker

per 8 feet of scaffolding plus 40

pounds of materials. GENERAL

REQUIREMENTS: When installed,

the platform support arm must be

set to match the pitch of the roof,

allowing for the installation of a

fully decked and level walk surface.

MOUNTING THE ROOF BRACKET:

1) All brackets shall be attached to

the roof with 20-penny nails. Use all

slots on mounting plate. 2) Position

bracket so that all nails penetrate

both the roof’s surface and the rafter

below. 3) Spacing between brackets

shall not exceed 8 feet. INSTALLING

PLATFORM: 1) wood platforms shall

not be less than 2 inches nominal

thickness and shall extend beyond

the support arm not less than 6

inches and not more than 12 inches.

2) Always use clear, straight-grained

wood free from knots or defects. 3)

If extended length platforms are re-

quired, use additional Roof Brackets

every 8 feet. 4) Secure to bracket by

nailing the platform to the bracket

using the hole provided in the plat-

form retainer. INSTRUCTIONS FOR

USE: 1) No more than one person

shall occupy any given 8 feet of a

Roofing Bracket Scaffold. 2) Always

use OSHA compliant fall arrest sys-

tem, guardrails, catch platforms or

other safety equipment as required

by Local, State or Federal OSHA

Regulations. 3) Roof Brackets are

intended for use by the experienced

tradesman. 4) OSHA Regulations re-

quire that employers provide training

in the use and care of this product.

CARE AND MAINTENANCE: 1) In-

spect all Roofing Brackets before

each use to be sure that there is

no damage or deformation, or de-

terioration from rusting. Discard if

necessary. 2) Do not throw or drop

from a building or onto a truck. 3) Do

not use if exposed to extreme heat

or cold. Discard at once. 4) Do not

use if wet or frozen.

INSTRUCTIONS FOR INSTALLA-

TION AND USE OF THE MODEL

#2503 & #3506 6”x 60 DEGREE,

#2504 & #3507 6”x 45 DEGREE,

#2505 & #3508 4”x 90 DEGREE

FIXED PITCH ROOFING BRACKET

(For use only as a material sup-

port): CAPACITY: 250 pounds of

roofing materials.. MOUNTING

THE ROOF BRACKET: 1) All brack-

ets shall be attached to the roof

with 20-penny nails. Use all slots on

mounting plate. 2) Position bracket

so that all nails penetrate both the

roof’s surface and the rafter below.

3) Spacing between brackets shall

not exceed 8 feet. INSTALLING

PLATFORM: 1) wood platforms shall

not be less than 2 inches nominal

thickness and shall extend beyond

the support arm not less than 6

inches and not more than 12 inches.

2) Always use clear, straight-grained

wood free from knots or defects. 3)

If extended length platforms are re-

quired, use additional Roof Brackets

every 8 feet. 4) Secure to bracket by

nailing the platform to the bracket

using the hole provided in the

platform retainer. INSTRUCTIONS

FOR USE: 1) Material supports are

not intended for use as a scaffold

or work platform.. 2) Always use

OSHA compliant fall arrest system,

guardrails, catch platforms or other

safety equipment as required by Lo-

cal, State or Federal OSHA Regula-

tions. 3) Roof Brackets are intended

for use by the experienced trades-

man. 4) OSHA Regulations require

that employers provide training in the

use and care of this product. CARE

AND MAINTENANCE: 1) Inspect all

Roofing Brackets before each use

to be sure that there is no damage

or deformation, or deterioration from

rusting. Discard if necessary. 2) Do

not throw or drop from a building

or onto a truck. 3) Do not use if

exposed to extreme heat or cold.

Discard at once. 4) Do not use if

wet or frozen.

INSTRUCTIONS FOR INSTALLA-

TION AND USE OF THE MODEL

#2501 & #3501 10”x 45 DEGREE,

MODEL #3504 8” x 45 DEGREE

PITCH ROOFING BRACKET (FOR

USE ON 12/12 PITCH ROOFS):

CAPACITY: One worker per 8 feet

of scaffolding plus 40 pounds of

materials. GENERAL REQUIRE-

MENTS: When installed, the plat-

form support arm must be set to

match the pitch of the roof, allowing

for the installation of a fully decked

and level walk surface. MOUNTING

THE ROOF BRACKET: 1) All brack-

ets shall be attached to the roof

with 20-penny nails. Use all slots on

mounting plate. 2) Position bracket

so that all nails penetrate both the

roof’s surface and the rafter below.

3) Spacing between brackets shall

not exceed 8 feet. INSTALLING

PLATFORM: 1) wood platforms shall

not be less than 2 inches nominal

thickness and shall extend beyond

the support arm not less than 6

inches and not more than 12 inches.

2) Always use clear, straight-grained

wood free from knots or defects. 3)

If extended length platforms are re-

quired, use additional Roof Brackets

every 8 feet. 4) Secure to bracket by

nailing the platform to the bracket

using the hole provided in the plat-

form retainer. INSTRUCTIONS FOR

USE: 1) No more than one person

shall occupy any given 8 feet of a

Roofing Bracket Scaffold. 2) Always

use OSHA compliant fall arrest sys-

tem, guardrails, catch platforms or

other safety equipment as required

by Local, State or Federal OSHA

Regulations. 3) Roof Brackets are

intended for use by the experienced

tradesman. 4) OSHA Regulations re-

quire that employers provide training

in the use and care of this product.

CARE AND MAINTENANCE: 1) In-

spect all Roofing Brackets before

each use to be sure that there is

no damage or deformation, or de-

terioration from rusting. Discard if

necessary. 2) Do not throw or drop

from a building or onto a truck. 3) Do

not use if exposed to extreme heat

or cold. Discard at once. 4) Do not

use if wet or frozen.

INSTRUCTIONS FOR INSTALLA-

TION AND USE OF THE MODEL

#2502 & #3505 6” X 90 DEGREE

& #3502 8”x 90 DEGREE FIXED

PITCH ROOFING BRACKET (For

use only as a slide guard or a

material support): CAPACITY: 250

pounds of materials. GENERAL

REQUIREMENTS: On roofs with

a 4/12 to 6/12 roof pitch, when in-

stalled as a slide guard, the scaffold

brackets should provide a platform

that is 90 degrees to the roof’s sur-

face at a point along the eave of the

roof. For roof slopes greater than 6/

12 up to 8/12 additional 90-degree

slide guards must be installed par-

allel to the first row no further than

every eight feet of roof slope. Ad-

ditional fall protection methods are

required on slopes 8/12 or greater.

When slope is greater than 4/12 and

the ground to eave height is greater

than 25 feet slide guards should not

be used. MOUNTING THE ROOF

BRACKET: 1) All brackets shall be

attached to the roof with 20-penny

nails. Use all slots on mounting plate.

2) Position bracket so that all nails

penetrate both the roof’s surface

and the rafter below. 3) Spacing

between brackets shall not exceed

8 feet. INSTALLING PLATFORM:

1) wood platforms shall not be

less than 2 inches nominal thick-

ness and shall extend beyond the

support arm not less than 6 inches

and not more than 12 inches. 2)

Always use clear, straight-grained

wood free from knots or defects.

3) If extended length platforms

are required, use additional Roof

Brackets every 8 feet. 4) Secure

to bracket by nailing the platform to

the bracket using the hole provided

in the platform retainer. INSTRUC-

TIONS FOR USE: 1) No more than

one person shall occupy any given

8 feet of a Roofing Bracket Scaffold.

2) Always use OSHA compliant fall

arrest system, guardrails, catch

platforms or other safety equip-

ment as required by Local, State

or Federal OSHA Regulations. 3)

Roof Brackets are intended for use

by the experienced tradesman. 4)

OSHA Regulations require that

employers provide training in the

use and care of this product. CARE

© Copyright 2003 • Qual-Craft

®

Industries • 1551 Central Street

PO Box 559 • Stoughton, MA 02072

AND MAINTENANCE: 1) Inspect all

Roofing Brackets before each use

to be sure that there is no damage

or deformation, or deterioration from

rusting. Discard if necessary. 2) Do

not throw or drop from a building

or onto a truck. 3) Do not use if

exposed to extreme heat or cold.

Discard at once. 4) Do not use if

wet or frozen.

Customer Support and Ordering Information

781-344-1000 • www.qualcraft.com

Advertising