Ramsey Winch RPH-15000T User Manual
Page 6

OM-914020-0199-A
4
HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) line pull (LB) first layer vs. working pressure (PSI) and (2) line speed, first layer (FPM) vs.
flow (GPM). A motor spool directional control valve is recommended.
*CAUTION: DO NOT EXCEED 20 GPM. IF EXCEEDED, MOTOR AND WINCH MAY BE DAMAGED.
PERFORMANCE CHARTS
SYSTEM REQUIREMENTS:
2140 PSI RELIEF VALVE SETTING
15 GPM FLOW RATE*
10 MICRON NOMINAL FILTRATION
1000 PSI MAXIMUM BACK PRESSURE
EMERGENCY STOP VALVE
INSTALLER MUST DETERMINE TYPE OF
EMERGENCY STOP REQUIRED. A MANUAL
CONTROL VALVE ALSO SERVES AS AN
EMERGENCY STOP VALVE. AN EMERGENCY
STOP VALVE MAY BE REQUIRED WITH OTHER
TYPES OF CONTROL VALVES.