Programming procedure – Rapid-Air AIR FEED / RAPID MASTER WITH KEYPAD User Manual

Page 8

Advertising
background image



The intent of this section is to

familiarize the operator with the

program flow and what to expect with

every keypress. Each screen on the

display will be reviewed with special

comments to help clarify what is

being asked on the screen. The

program flow is broken down into

sections with the main menu being

the home position. Reviewing the flow

chart in the back of this manual will

help in understanding the sections.

Section 1

f1=cycles per hit entry

Section 2

f2=manual mode

setup parameters

Section 3

f3=automatic

The first screen to be displayed on the

operator terminal will look like this:

rapid-Air Corporation

rockford, IL 61109

After a few seconds, the display

will clear and the following display

will appear:

feed cycles/hit=XX

f1=set cycle per hit

f2=manual mode

f3=automatic mode

Select F1=set cycles per cut

The first step in programming the cut to

length feed is to input the correct cycles

to achieve the desired feed length.

When the operator selects F1 on the

keypad, the screen will change to:

Set feed cycles per hit

_____________ “Enter”

A number must be

entered to continue

When the enter key is pushed, the

screen reverts back to the main menu.

Select F2-Manual. The following

screen appears:

Manual keys are now active

** USE CAUTION **

f4=exit to main menu

1. When pressing the F4 key the

display reverts back to the main

menu.

2. All manual keys are now active.

Pressing any labeled key will

activate a movement.

CAUTION: Make sure there is air

to the cutter before cycling or the

system will lock up. To unlock, the

main power has to be cycled.

3. Pressing the “Feed Button” will

cause the feed to move the

number of cycles that was entered.

4. Pressing the “Ram Cycle Button”

will cause the ram to cycle one time.

5. Pressing the “Single Cycle

Button” will cause the feed and

ram to perform one complete cycle.

6. Press the “Total Reset” button and

the following display appears.

Total Count = XXXXXX

f1=reset to Zero

f4=Exit Display

a. Pressing the F1 key will cause

the total count to be all zeros

b. Pressing the F4 key will take you

back to the main menu.

7. Press the “Ram Time Button” and

the following screen appears.

ram Dwell Time =XX

f1=Set Dwell Time

f4=Exit Display

a. Pressing the F1 key will display

a screen which will force you to

enter a dwell time before leaving

the screen.

programming procedure

Operator Input Terminal – programming procedure – Standard Software

b. Pressing the F4 key will take

you back to the main menu.

8. Press the “Clamp Air Button” and

the following screen appears:

feed Air Selection

f1=Turn feed Air On

f2=Turn feed Air Off

f4=Exit

Use this feature when loading

material into the air feed.

9. Press the “Diagnostics Button”

and the following display appears.

feed at Main SW-Off

feed at Stop SW-Off

ram ret’d SW-ON

f4=Next

Press F4 and the next screen

appears.

ram Door Closed SW-Off

feed Door Closed SW-Off

f4=Exit

Each time the switch changes

state, the screen switches to off

or on. If the switch is energized,

the screen displays - on. If the

switch is de-energized, the screen

displays- off.

10. Press the “Count Display Button”

and the following screen appears.

part Count Display

Total Count=XXXXXX

Batch Count=XXXXXX

f4=Exit

Pressing the F4 “Exit” key and the

screen reverts back to the previous

screen.

Advertising