Programming procedure, Continued) – Rapid-Air SMART MINI-SERVO GAG FEED User Manual

Page 10

Advertising
background image

0

ProGramminG ProCedUre

(ContinUed)

F1, batch/total, on the

“RAMP/COUNTER” screen leads to:

EXIT

SET COUNTER vALUES

SET

RESET

BATCh/ TOTAL

F1, set batch, on the “SET COUNTER

VALUES” screen leads to “BATCH

SET” screen discussed above in

SECTION 3.

F2, reset totals, on the “SET COUN-

TER VALUES” screen resets the total

counter to 000000.

F6, exit, will return to the “RAMP/

COUNTER” screen.

F2, speed/acc/dec, on the “RAMP/

COUNTER” screen leads to:

EXIT

ALTER PERCENTAGES

%ACC %DEC %SPEED

F6, exit, will return to the “RAMP/

COUNTER” screen.

F1, % acc, allows the acceleration

percentage to be altered with:

ENTER PERCENT OF ACC

MAX ACCEL = 000 %

MAXIMUM RATE (1 - 100) %

ENTER kEY TO EXIT

The enter key returns the display to

the “ALTER PERCENTAGES” screen.

F2, % dec, allows the deceleration

percentage to be altered with:

ENTER PERCENT OF DEC

MAX DECEL = 000 %

MAXIMUM RATE (1 - 100) %

ENTER kEY TO EXIT

The enter key returns the display

to the “ALTER PERCENTAGES”

screen.

F3, % speed, allows the speed per-

centage to be altered with:

ENTER PERCENT OF SPEED

MAX SPEED = 000 %

MAXIMUM RATE (1 - 100) %

ENTER kEY TO EXIT

The enter key returns the display

to the “ALTER PERCENTAGES”

screen.

SECTION 6 F6 - CYCLE ROLLER
F6, cycler roller, on the“MAIN

MENU” screen displays the following

screen.

EXIT

CYCLE FEED ROLLERS

OPEN

CLOSE

ROLLER ROLLER

This allows the operator to manually

open and close the rollers.

SECTION 7 “.” - OUTPUTS DURATION
Pushing a “.”, outputs duration, while

in the “MAIN MENU” screen displays

the following screen:

OUTPUT DURATION

ENTER 0.000 FOR NONE

END FEED TIME=0.000

OUTPUTS TIME=0.000

This allows the operator to set

the duration of the END OF FEED

and SEQUENCE OUTPUTS. The

default duration of outputs is 250 mil-

liseconds. Please refer to the wiring

schematic for the locations of

the END OF FEED and SEQUENCE

OUTPUTS.

Depressing F3, auto mode, while on the

“AUTOMATIC MODE” screen will display:

EXIT

AUTO TOTAL = 000000

JOB # =00 LENGTh = 00.000

SPM = 000 SPEED = 000 %

The automatic cycle will continue

until the F6 key, exit, is pressed.

SECTION 4 F4 - JOB vALUES REvIEw

F4, job values, on the “MAIN MENU”

screen displays the following screen

until F6, exit, is pushed. The following

screen appears:

JOB # 00 SEQUENCE = 01

ENTER ThE SEQUENCE #

ThEN PUSh ThE ENTER kEY

Enter the sequence which is to be
reviewed and press

. The next

screen lists the current active job

number, sequence, the feed length,

number of repetitions, output se-

quence, speed, and whether the pilot

release is used:

JOB # 00 SEQUENCE = 01

FL = 00.000 REPEAT = 00

OUTPUT = 11111 PILOT = 0

SPEED = 003 F6 = EXIT

F6 exits to the MAIN MENU.

SECTION 5 F5 - RAMP/COUNTER

F5, ramp/counter, on the “MAIN

MENU” screen displays the following

screen:

EXIT

BATCh/

SPEED/

TOTAL

ACC/DEC

Advertising