Rapid-Air CABINET REEL WITH DISPLAY KEYPAD User Manual

Page 11

Advertising
background image

11

5. Percent speed function set too low.
a. Adjust percent speed function to 100%.
6. Fuses blown.
a. Check fuses & circuit breaker.
7. No AC voltage at DC drive board.
a. Check wiring.
8. Check Signal voltage between P2 to P1 on DC drive.
0-6 VDC—Ramm
0-9 VDC—Regen Drive
while moving dancer arm.
a. If there is a signal, check continuity between I1 & I2.
If no continuity, replace D.C. drive or call factory.
10. Check pico fuse on 69100804 board (F1).
a. Replace fuse, 1 amp pico fuse—call factory.