3 periodic check points, 3 periodic check points -5, Periodic check points – Proface APL3000B - Node Box PC User Manual

Page 74: 5 4.3 periodic check points

Advertising
background image

Chapter 4 Maintenance

4-5

4.3

Periodic Check Points

To keep your PS-A unit in its best condition, please inspect the following points periodically.

„ PS-A Operation Environment

•

Is the operating temperature within the allowable range?

(PS-3650A Series)

(PS-3651A Series)

•

Is the operating humidity within the specified range?

10 to 90%RH (Not condensing, wet bulb temperature: 39°C or less, or with HDD 29°C or less.)

•

Is the operating atmosphere free of corrosive gasses?

When using the PS-A unit inside a panel, the ambient environment refers to the interior of the

panel.

„ Electrical specifications check

•

Is the input voltage appropriate?

AC Power Supply Type: AC85 to 265V, 50/60Hz

DC Power Supply Type: DC19.2 to 28.8V

„ Related Items

•

Are all power cords and cables connected properly? Have any become loose?

•

Are all mounting brackets holding the unit securely?

•

Are there many scratches or traces of dirt on the installation gasket?

When using HDD

When not using HDD

5 to 50°C

0 to 50°C

When using HDD

When not using HDD

5 to 45°C

0 to 50°C

Advertising