3.3

Wiring Precautions

This section describes the procedures and precautions for wiring power cords.

3.3.1

Connecting the Power Cord

„ AC Connections

Be sure to confirm that power is not being supplied to the PS-B unit before wiring . Failure

to do so can result in an electric shock.

Supplying a power voltage other than that specified will damage the power source and the

PS-B unit.

Since there is no power switch on the DC type PS-B unit, be sure to attach a breaker-type

switch to its power cord.

When the FG terminal is connected, be sure the wire is grounded.

• When the FG terminal is connected, be sure the wire is grounded. Not grounding

the PS-B unit will result in excess noise and vibration.

• The SG and FG terminals are connected internally in the PS-B unit.

When connecting the SG wire to another device, be sure that the design of the

system/connection does not produce a shorting loop.

The PS-B units is designed to use AC100V to 240V input. Supplying a power voltage other

than that specified will damage the power source and the PS-B unit.