Chapter 2 System Setup

2-11

„ I/O Device Configuration

Specifies the address and interrupt level of the I/O ports. Point the cursor to the [I/O Device Configuration] on

the [Advanced] screen and press the [Enter] Key, so that the following screen will be displayed.

Onboard Serial Port 1

Specifies an enabled/disabled state for the COM1. Select from [Disabled] or [Enabled]. The factory default

setting is [Enabled]. In addition, the factory default setting for Base I/O Address is [3F8], and for Interrupt is

[IRQ 4].

Onboard Serial Port 2

Specifies an enabled/disabled state for the COM2. Select from [Disabled] or [Enabled]. The factory default

setting is [Enabled]. In addition, the factory default setting for Base I/O Address is [2F8], and for Interrupt is

[IRQ 3].

Onboard Serial Port 3

Specifies an enabled/disabled state for the COM3. Select from [Disabled] or [Enabled]. The factory default

setting is [Enabled]. In addition, the factory default setting for Base I/O Address is [3E8], and for Interrupt is

[IRQ 11].

The Battery unit and driver communicate through COM3, as the battery output interface. When

using a battery unit, set Onboard Serial Port 3 to [Enabled].