Specifications, Ordering information, Your authorized watlow distributor – Watlow E-Safe Hybrid Relay Rev B User Manual

Page 4

Advertising
background image

Declaration of Conformity

Series E-Safe Relay

Watlow Winona, Inc.
1241 Bundy Blvd.
Winona, MN 55987 USA

Declares that the following product:

Designation:

Series E-Safe

Model Numbers:

ES (20 or 40) - 3 (024, 120, 220) - ACCE

Classification:

Mechanical Relay, AC-51 Utilization
Category for

Resistive Loads. Installation

Category II, Pollution degree 2

Rated Voltage and Frequency:

Load 24-240 V~(ac) 50/60 Hz,
Control Signal 24 V~, 120 V~ or 200-240V~

Rated Power Consumption:

Load 20 A or 40 A depending on model.
Control Signal 15 VA Max.

Meets the essential requirements of the following European Union Directives by using the relevant
standards show below to indicate compliance.

89/336/EEC Electromagnetic Compatibility Directive

EN 60947-4-3

2000

Low-voltage switchgear and controlgear - Contactors and
motor-starters - AC semiconductor controllers and contactors
for non-motor loads. Industrial Immunity, Class B emissions.

EN 61000-4-2

1995

Electrostatic Discharge Immunity

EN 61000-4-3

1996

Radiated Field Immunity

EN 61000-4-4

1995

Electrical Fast-Transient / Burst Immunity

EN 61000-4-5

1 9 9 5 , A 1 : 1 9 9 6

Surge Immunity

EN 61000-4-6

1996

Conducted Immunity

EN 61000-4-11 1994

Voltage Dips, Short Interruptions and Voltage Variations Immunity

EN 61000-3-2

2000 ED.2.

Harmonic Current Emissions

73/23/EEC Low-Voltage Directive

EN 60947-4-3

2000

Low-voltage switchgear and controlgear- Contactors and
motor-starters - AC semiconductor controllers and contactors
for non-motor loads.

Raymond D. Feller III

Winona, Minnesota, USA

Name of Authorized Representative

Place of Issue

General Manager

February 2004

Title of Authorized Representative

Date of Issue

Signature of Authorized Representative

Ordering Information

(2145)

Part Number

E S _ _ - _ _ _ _ - _ _ _ _

Amperage

20 = 20 amp
40 = 40 amp

Number of Poles

3

= 3-pole

Control Voltage

024 AC = 24 V~
120 AC = 120 V~
220 AC = 220 V~

Label Options

00 = Standard Product
CE = With CE mark

Specifications

(2146)

Control Mode
•

Zero cross switching output

•

Form A outputs, without arcing

•

Cycle rate: 30 cycles per minute, maximum

Input Command Signal
•

24V~ (+10% / -10%) @ 0.375 Amperes

•

120V~ (+10% / -10%) @ 0.075 Amperes

•

220V~ (+15% / -20%) @ 0.041 Amperes

•

50/60 Hz

•

Input Surge current and pulse characteristics

24 volt input = 24 Amp surge, less than 10VA required (0.41 A)
120 volt input = 16 Amp surge, less than 12VA required (0.101 A)
220 volt input = 8 Amp surge, less than 14VA required (0.063 A)

•

Power factor approximate 0.58, 100 uSec pulse width or surge.
Note:
Do not use a RC snubber on the Esafe input or the temperature con-
trol command signal output

Output Rating
•

20A to 40A max. per pole into a resistive load,
model number dependent

•

208/240V, 50/60 Hz, phase to phase

•

3-pole

•

Leakage current: 0.5mA max.

Operating Life
•

1,000,000 switching cycles at maximum rating

Weight/Dimensions
•

Weight: 0.560 Kg (1.25 lb)

•

96.0 mm (3.78 in) high x 82.3 mm (3.24 in) wide
x 90.2 mm (3.55 in) deep

Terminals
•

Control input: Compression, accept 0.2 to 6 mm2 (# 22 -10 AWG)
wire, torque to 0.8 Nm (7 in-lbs) maximum

•

Output: Compression, accept 2.5 to 16 mm2 (# 14- 6 AWG) wire,
torque to 3.95 Nm (35 in-lbs) maximum

Operating Environment
•

Operating temperature, -30 to 55°C/-22 to 130°F

•

5 to 85% RH, non-condensing

•

Storage temperature, -40 to 85°C/-40 to 185°F

Mounting
•

Fits footprint of definite purpose relays and most 30 to 50 amp
mercury relays

Agency Approvals
•

UL® 508 listed, C-UL, File #E213822