Step 5 set controller security – Watlow MINICHEF 2000 User Manual
Page 30

H a r d w a r e & S o f t w a r e S e t u p G u i d e
Wa t l o w M
I N I
C
H E F
2 0 0 0
■
2 9
Step 5 Set Controller Security
To Set Menu Security Lock
Return to the Configuration Mode, to the [Setup] Function, and program the [Loc``]
Parameter to adjust end-user access.
When
[loc``]
is set to
[``yes]
the end user does not have access to the Menu
Programming Mode and can only view parameter values.
When
[loc``]
is set to
[```no]
the end user has access to the Menu Programming
Mode and can change parameter values.
To return to the Operation Mode, press the Enter key twice.
To Set Application Number Security Lock
Return to the Configuration Mode, to the [ETyPE] Function, and the [A_Loc]
Parameter to adjust end-user acess.
When [A_Loc] is set to
[``yes]
the user cannot change the Application Number.
The application number is secure from inadvertant changes.
When [A_Loc] is set to
[```no]
the user can change the Application Number.
To return to the Operation Mode, press the Enter key twice.
S t e p 5 S e t C o n t r o l l e r S e c u r i t y