En g l is h english, Installation steps – Pfister R89-8YPY User Manual

Page 2

Advertising
background image

E

N

G

L

IS

H

ENGLISH

ENGLISH

Thank you for purchasing this Price Pfi ster product. All Price Pfi ster products are carefully engineered, and factory tested to provide long
trouble-free use under normal conditions. This product is easy to install using basic tools and our easy to follow illustrated instructions. If you
have any questions regarding your product installation call 1-800-Pfaucet (1-800-732-8238)

.

1 BEFORE PROCEEDING

WARNING: Read all the instructions completely before proceeding. Price

Pfi ster recommends calling a professional if you are uncertain about installing

this product!

This product should be installed in accordance with all local and state plumbing

and building codes.

WARNING: This product has been designed for use with the Price Pfi ster

0X8 series pressure balancing valve. It will not work with any other product.

Please review the 0X8 valve installation instructions before installing this

product.

2 SHUT OFF WATER SUPPLY

Locate water supply inlets and shut off the water supply valves. These are

usually found near the water meter. If you are replacing an existing unit, remove
the old unit and clean the mounting surface thoroughly.

3 TOOLS RECOMMENDED

• PTFE plumber's tape or thread sealant

• Philips head screwdriver

• Adjustable wrench • Pipe wrench

• Flashlight

• Cloth

Your installation will require a pipe nipple for the spout installation as well as

other additional tools.

This product comes with a Hex Wrench for tightening a set screw into the

Hub.

4 CHECKING THE CONTENTS OF THE BOX

Upon opening the box, check to ensure that all of the following items are included.

A Gasket Flange

B Trim Flange

C Washer

D Retainer Sleeve

E Extension Stem

F Hub & Handle

G Set Screw

H Hex Wrench

J Diverter Spout

K Shower Arm

L Shower Head

M Shower Flange

If any of these items are missing, please contact Price Pfi ster Consumer Service

at 1-800-Pfaucet (1-800-732-8238).

5 WORK AREA INSPECTION

Verify that the hole sizes and positions in the wall are correct.

6 PLASTERGUARD OPTIONS

A. For installation using plasterguard, knock out Center Section (6B) from Plasterguard

(6A). The use of plasteguard is optional for standard installations.

B. For installation without plasterguard, remove Screws (6C), and

Plasterguard (6A).

4

5

6

INSTALLATION STEPS

3

2

30”

Tub & Shower

48”

Tub & Shower

8” Min.

30”

Shower Only

48”

Shower Only

1

1

/

4

” Dia.

4

3

/

4

” Dia.

4” Dia. for Thin

Wall Installation

1

1

/

4

” Dia.

A

B

A

B

C

D

E

F

G

H

J

K

L

M

6B

6A

6C

6A

Advertising