En g l is h english, Maintenance & care – Pfister R89-8YPY User Manual

Page 4

Advertising
background image

E

N

G

L

IS

H

ENGLISH

ENGLISH

13 TUB SPOUT FUNCTION

When the valve is turned on, water normaly fl ows through the Tub Spout (13A).

To activate the shower, turn valve on and pull the Knob (13B) up. Hold on until

water fl ows continiously from the shower arm.

15 SHOWER HEAD INSTALLATION

Thread Shower Head (15A) onto Shower Arm (15B).

Make sure Shower Head (15A) is securely tightened to Shower Arm

(15B).

CAUTION: Maintenance

DISASSEMBLY

1. Replacement parts may be available at the store where you purchased

your faucet.

2. When replacement parts are not available, please write or call Price

Pfi ster Consumer Service.

3. Always turn off water and relieve pressure before working on your

faucet.

NOTE: Trim Care

Cleaning Instructions:
For all Handles and decorative fi nishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:

Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!

12 VALVE FUNCTION

By rotating the Lever Handle (12A) slightly counterclockwise, the valve will

be fully activated to the “COLD” position. The water temperature can be

increased by continuing to rotate the Lever Handle (12A) in a counterclockwise

direction.

14 FINAL FLUSHING

For fi nal fl ushing, turn valve on and allow water to run through the Tub Spout

(14A) for several minutes. Pull Spout Knob (14B) up to allow water to run through

Shower Arm (14C). Allow water to run for several minutes untill all foreign mater

clears the line.

UP

For

Shower

MAINTENANCE & CARE

13

12

14

15

4

FULL HOT

FULL COLD

CLOSED

OPEN

12A

15A

15B

14A

14B

14C

13A

13B

Advertising
This manual is related to the following products: