OPTIONAL SPECIFICATIONS (For Explosion Protected Type)


OPTIONAL SPECIFICATIONS


Note 1: Option only available with /FF1 Option.

ORDERING INFORMATION

Specify the following when ordering:
1. Model and suffix codes.
2. Option codes.
3. Tag number
4. Calibration range desired (optional)

OPTIONS


The MLX is fully field configurable from the front panel. To order a
pre-configured unit, specify the /ENG option followed by the desired
setpoints (zero, full scale, and engineering units).

Item

Description

Code

Canadian Standards
Association (CSA)
Canadian Standards
Association (CSA)

CSA Intrinsically Safe/CSA Explosionproof/ CSA Dust-Ignition-Proof /CSA Non-incendive Approval

Certified to: CSA C22.2 No. 25, CSA C22.2 No. 30, CSA C22.2 No. 157, CSA C22.2 No. 213,
CSA C22.2 No. 60079-0, CAN/CSA E60079-11
Explosionproof/Dust-Ignition-Proof for:

Class I, II, III; Groups A - G; Divisions 1 & 2.

Class I, Zone 1, Group IIC T4.

Tamb. –40°C to 80°C

Intrinsically Safe for:

Class I, Division 1, II, III; Groups A - G; Divisions 1 & 2.

Zone 20, Class I, Zone 0

AEx ia IIC T4

Tamb. –40°C to 80°C

Entity parameters: Ui=24 V, Ii=150 mA, Pi=0.65 W, Ci=0 nF, Li=0 H

Non-Incendive for:

Class I, II, III; Groups A - D, F, G; Divisions 2.

Class I, Zone 2, Group IIC T4.

Tamb. –40°C to 80°C

Enclosure rating: "Type 4X."
Temperature Class: T4
Ambient Temperature: –40°C to 80°C

CU1

IECEx Scheme

IEC Intrinsically Safe/IEC Flameproof/IEC Non-Incendive Approval

Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2008, IEC 60079-11:2011,
IEC 60079-26:2009, IEC 60079-31:2008
Explosionproof/Dust-Ignition-Proof for:

Ex d IIC T4 Gb

Ex tb IIC T135 Db

Intrinsically Safe for:

Ex ia IIC T4 Ga

Entity parameters: Ui=24 V, Ii=150 mA, Pi=0.65 W, Ci=0 nF, Li=0 H

Non-Incendive for:

Ex nA IIC T4 Gc

Ambient Temperature: –40°C to 80°C
Enclosure: IP66 and IP67

SU2

Combination of
Approvals

Combination of FU1, CU1 and KU21 Approvals

V1U

INMETRO (Brazil)
Certificate

INMETRO Intrinsically Safe/INMETRO Flameproof Approval (Pending)

BU1

GOST (Russian)
Certificate

Russian GOST certifícate (Pending)

QR1

Item

Description

Code

Coating

Epoxy resin coating
Polyurethane-Epoxy Anti-corrosion coating

Note 1

X1

X2

Note 1

Calibration

Calibration range and scale

ENG

Stainless steel tag
plate

Stainless steel tag screw attached to housing
Stainless steel tag wired to housing

SST

SSW

Paint

Light Blue (RAL # 5012)
Orange (RAL # 2008)
Red (

Munsell # 7.5 R4/14

)

Mint Green
Silver (RAL # 9006)
Yellow (RAL # 1018)
Gray (RAL # 7046)

P1
P2
P3
P4
P5
P6
P7