1

2

3

App1

App2

Index

2.9

Operating a Numeric Out Object

The numeric out object sends numerical values to the I/O Channel host.

The numeric out object displays the values from the channels corresponding to output

channels.

Procedure

1.

If you click a numeric out part in AddObserver panel whose direct output property

was turned OFF in AddObbserver Builder, the following dialog box appears.

2.

Change the value, then click the Send button.

Numerical values are sent to the I/O Channel host.

If you click a numeric out part in AddObserver panel whose direct output property

was turned ON in AddObbserver Builder, the dialog box is not displayed, and the

display area of the numeric out part becomes a numeric input screen.

Note

• If an error occurs in I/O Channel, the error is not displayed. Errors are likewise not

displayed when communication with the server (I/O channel host) is broken, or if there is a

problem between the server and connected instruments.

• If communication with the monitor server fails for some reason such as a cable becoming

disconnected during transmission, the output values are not resent even if the cable is

reconnected.

• If the server (GateCONTROL) determines that the output value falls outside of the range on

the instrument (temperature controller) the value is not sent to the instrument.