Yokogawa JUXTA FR5V RTD Converter (Free Range Type) User Manual

User's manual, Models fr5a, fr5v rtd converter (free range type), Checking product specifications and package

Advertising
background image

User's

Manual



Thank you for purchasing the JUXTA Signal Conditioner.

Please read through this manual before use for correct handling.

Network Solutions Business Division

2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 Japan

Phone: +81-422-52-7179 Facsimile: +81-422-52-6619

IM 77J08R05-01E

1st Edition Jan.2007 (YK)

CAUTIONARY NOTES FOR SAFE USE OF THE

PRODUCT

This User’s Manual should be carefully read before installing and
operating the product. The following symbol is used on the prod-
uct and in this manual to ensure safe usage.

This symbol is displayed on the product when it is
necessary to refer to the User's Manual for information
on personal and instrument safety. This symbol is
displayed in the User's Manual to indicate precautions
to avoid danger to the operator, such as an electric
shock.

The following symbols are used only in this manual.

NOTE

D r a w s a t t e n t i o n t o e s s e n t i a l i n f o r m a t i o n f o r
understanding the operations and/or functions of the
product.

CHECKING PRODUCT SPECIFICATIONS AND

PACKAGE

(1) Checking the Model and Product Specifications

Check that the model and specifications indicated on the
nameplate attached to the main unit are as ordered.

(2) Packaged Items

Check that the package contains the following items:

FR5A or FR5V: 1
Mounting block: 2
Tag number and range label : 1 each
Mounting screw (M4 x 0.7): 2
User’s Manual (this manual : IM 77J08R05-01E)

GENERAL

The FR5A/FR5V is a compact, front terminal connection and
free range type RTD converter that is connected to an IEC/JIS-
standard resistance temperature detector (RTD) to convert tem-
perature signals into isolated DC current or DC voltage signals.

Selection of input type, I/O range setting, burnout setting,
output adjustment, I/O monitoring, and loop back test can be
made using the optional Parameter Setting Tool (VJ77) or
Handy Terminal (JHT200).





MODEL AND SUFFIX CODES

Model

Suffix codes

Description

FR5A

-  *C / RTD Converter

FR5V

(Free Range Type)

Input

-1

Pt100 (IPTS-68:JIS'89)

-2

JPt100 (JIS'89)

-3

Pt50 (JIS'81)

-4

Pt100 (ITS-90)

-0

Custom order

Output

A

4 to 20 mA DC

FR5A

B

2 to 10 mA DC

C

1 to 5 mA DC

D

0 to 20 mA DC

E

0 to 16 mA DC

F

0 to 10 mA DC

G

0 to 1mA DC

Z

(Custom order)

Direct current signals

1

0 to 10 mV DC

FR5V

2

0 to 100 mV DC

3

0 to 1 V DC

4

0 to 10 V DC

5

0 to 5 V DC

6

1 to 5 V DC

7

-10 to 10 V DC

0

(Custom order)

Direct voltage signals

Style code

*C

Style C

Burnout

/BU Up
/BD Down
/BN None

Temperature unit

/DF

Fahrenheit (°F) display function

Models FR5A, FR5V

RTD Converter

(Free Range Type)

Advertising