HOSE EVACUATION

It's important that Air not be introduced into the A/C System during a Charging procedure. If a Deep
Vacuum procedure was performed previously, the following Hose Evacuation Procedure is not
required. If the service valves on the hoses have been open, the following procedure must be
performed:

Figure 4 Hose Evacuation

To Evacuate Hoses, refer to Figure 4 and follow these steps:

1.

Close Red and Blue Hose Valves.

2.

Open High and Low Gauge Valves.

3.

Press top (ON) of rocker switch marked RECOVER/RECYCLE.

4.

Let the TC670V run until a vacuum is seen on the Low Side Gauge.

5.

Turn High and Low Gauge Valves to OFF.

6.

Press bottom (OFF) of rocker switch marked RECOVER/RECYCLE. All Air has now been
removed from the Hoses.

7.

Vent any Non-condensable Gas as described in the previous section.