Refrigerant Technologies, Inc.

May 24, 1993

Page 4

Figure 1 Hose Connections

PREPARATION FOR USE

Place the External Cylinder on the
Weight Scale Platform on the rear of
the RR750X.

Connect the four hoses to the External
Cylinder as shown in Figure 1.

NOTE:

Color standards for cylinder valve
knobs were changed by the
manufacturer during 1992.

Therefore, do not depend on color to
indicate liquid or vapor valves on the
External Cylinder. Look for
“LIQUID” or “VAPOR” embossed
on the knobs.

Tighten fittings FINGER-TIGHT only. Over tightening may cause damage to the fittings or valves
and result in leaks.

It is recommended that ALL connections be checked with an electronic leak detector each time hoses
are reconnected.

RECYCLE OPERATION

Set valves on the RR750X as follows in preparation for performing a Recover/Recycle operation:

!

Red Valve on External Cylinder OPEN (Counter-clockwise)

!

Blue Valve on External Cylinder OPEN (Counter-clockwise)

!

Ball Valve on Red Hose OPEN (Handle parallel to hose)

!

Ball Valve on Blue Hose OPEN (Handle parallel to hose)

!

Yellow Filter Bypass Valve OFF (Handle vertical)