Empty used tank, Fill new tank – MAHLE RTI BFX-1 User Manual

Page 10

Advertising
background image

IMPORTANT:

Test drive vehicle after service to verify proper
brake system performance.

Page 9

Empty Used Tank

1.

On the Used Fluid Tank, disconnect the fluid line coupler as well as the electrical float
switch connection.

2.

Twist the cap counterclockwise to remove.

3.

Empty into an appropriate bulk waste container.

4.

Replace cap on Used Fluid Container (turn clockwise).

5.

Connect fluid line coupler as well as the electrical float switch connection and place tank in
rear of BFX.

Note:

Follow all federal and local laws and regulations when disposing of
hazardous material.

Warning: Not removing the electrical connection can cause serious damage that may

make the BFX nonoperational.

Fill New Tank

1.

On the New Tank, remove the New Tank Float Stopper and pour new brake fluid into the
opening.

2.

Replace Stopper into New Fluid Tank securely.

Note:

For varying new tank heights slide the New Tank Float Stopper up or down
the New Tank Float until the appropriate height is obtained.

Warning: Failure to properly set the height of the New Tank Float Stopper can result in

a New Tank Float malfunction which could allow air into the brake system.

Warning: Brake fluid is Hygroscopic (absorbs moisture). It is recommended that the

new fluid container is emptied if unit will not be operated for an extended
period of time.

Advertising