Troubleshooting & Maintenance

The BFX-1 has five filters to prevent any debris from entering internal components and
possibly causing problems. The location of the filters is illustrated below.

New Fluid Filter:

Filters fluid from the new fluid tank. If the fluid flow seems slow while trying
to fill the master - check and clean this filter.

The filter is inside the control box on top of the machine. Remove screws
and gently raise the control box to access the filter. Unscrew the cover
and clean the screen as required.

Vacuum Filter:

Filters fluid in the four vacuum hoses which attach to the bleeder valves. A
filter is mounted in-line on each of the vacuum hoses. If the fluid flow
seems slow from the bleeders - check and clean these filters.

These filters can be accessed through the door on the side of the BFX-1.
Remove hoses from both ends of the filter and try clearing the filter with
compressed air. Replacement filters (P/N 026-80372-00) can be ordered
from RTI.