Hl w, Technical specification, Limits of application – Stuart Turner Submersible Supersub User Manual
Page 4: Fig. 1 (dimension key)
Advertising

- 4 -
TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
LIMITS OF APPLICATION
Model
Max.
Liquid
Temp.
o
C
Min.
Liquid
Temp.
o
C
Max.
Immersion
Depth
(m)
Min.
Immersion
Depth
(mm)
Max.
No.
Starts/h
Max.
Head (pump
closed valve)
(m)
Supersub 230A
35
4
7
90
30
8.3
Supervort 140A
35
4
7
120
30
5.0
Supervort 240A
35
4
7
120
30
7.4
Model
Supply
Max. Watts
Consumed
Nominal
Watts
Output
(Motor)
Full
Load
Current
(AMPS)
Enc.
Rating
Duty
Rating
Dims (mm)
Gross
Weight
(packed)
kg
No. of
Pump
Stages
L
W
H
Supersub 230A
230/1/50
466
400
2.1
IPX8
Continuous
260
158
320
5.0
1
Supervort 140A
230/1/50
320
225
1.4
IPX8
Continuous
260
158
334
5.0
1
Supervort 240A
230/1/50
513
425
2.3
IPX8
Continuous
260
158
334
5.1
1
H
L
W
Fig. 1 (Dimension Key)
Advertising
This manual is related to the following products: