A suitable method of connection would be via a double pole switched, fused connection
unit complying with BS 1363-4.
The connection unit should be mounted in an easily accessible position and should be
labelled if confusion is possible to allow easy identification of the pump isolating switch.
WARNINGS:
A residual current device having rated current not exceeding 30 mA
MUST be installed in the supply circuit.
Isolate power supply before putting your hands in the liquid.
The pressure control module must be protected from the elements.
Wiring
The supply cord that connects the remotely mounted pressure control module to the
mains supply is not provided. This cord must be sourced and provided by the installer.
Cord selection should be chosen in accordance with the current involved/surrounding
conditions and the fuse size required to protect the factory fitted pump supply cord (see
fuse section).
The pump must also be connected to the pressure control module using the factory fitted
pump supply cord which is provided with ends bared.
For information on cable fitting and connection, consult the wiring diagram and cable
gland fitting instructions for the control module.
WARNING: The supply cord of this pump cannot be replaced. If the cord
is damaged, the pump should be scrapped.
Wiring Diagrams
The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It
is essential that any disturbance of this internal wiring is avoided and the
factory routing and securing of all internal wiring is always maintained.
MOTOR
50 Hz
1 Phase
230 V
SUPPLY
L
N
E
FUSE
V
U
N
L1
MODULE
CONTROL
PRESSURE
E
GREEN/YELLOW
BLUE
BROWN
3
4
5
6
2
1
Fig. 3