REMOVAL:

Using the supplied Allen Wrench and carefully loosen (counter-clockwise) the Allen Head Bolt in the mount, when

you have removed the Allen Head Bolts the laser can be removed from the rail.

ON/OFF SWITCH FUNCTION:

The laser is equipped with a Side to Side ON/OFF Switch. First, make sure the laser is pointed in a safe direction. To

turn the laser ON, push the right side of the ON/OFF Switch to the Left. To turn the laser OFF, push the left side of the
ON/OFF Switch to the Right.

WINDAGE AND ELEVATION ADJUSTMENT:

To adjust the Windage of the laser, insert the provided Allen wrench into the Windage Set Screw located on the Left

side of the laser body. Turn the Windage Set Screw Clockwise to adjust Left and Counter-clockwise to adjust Right.

To adjust the Elevation of the laser, insert the provided Allen wrench into the Elevation Set Screw located on the bottom of
the laser body. Turn the Elevation Set Screw Clockwise to adjust laser Down and Counter-clockwise to adjust the Laser Up.

TIP: The quickest method to zero your laser is to first adjust the laser to your iron sights. Then make the
necessary fine adjustments at the shooting range.


BATTERY REPLACEMENT:

To replace the batteries in your laser, first turn the laser to the OFF

position. The Battery Cap is the round cap with a slot machined into it, located on
the bottom of the laser body. Use a flat blade screw driver or small coin to turn

the Battery Cap Counter Clockwise for removal.

Once the Battery Cap is removed, remove the old batteries and discard it

in the proper manner. The 2

nd

battery will sometimes stick to the inside of the

Battery Cap. Only use new AG13 or LR44 batteries with the laser. DO NOT use a

different type of battery, as this may cause damage to the unit. DO NOT mix old
batteries with new batteries.

Place the new batteries into the laser, making sure that both of the

battery’s Positive Sides (+) are facing out and that the batteries are centered in
the cavity. Once the batteries are in place, place the Battery Cap over the top
battery and screw the cap Clockwise until the cap is flush with the bottom of the

laser body. If there is some resistance or the cap does not close flush, make sure
the bottom battery is centered in the cavity, so that the cap can screw down and

around both batteries. Next, test the function of the laser. If the laser does not
turn ON, check to make sure that both of the batteries are installed correctly.

9) Elevation Adjustment
10) Windage Adjustment

11) Battery Door
12) AG13 or LR44 type Batteries

(Two Each Required)