INSTALLATION OF STI-9880 & STI-9881 FLUORESCENT LIGHT FIXTURE GUARD
All specifications and information shown were current as of publication, and are subject to change without notice.
9880 JUNE2011
19013
#10 x 1 1/2 in. SCREW
(10) PROVIDED
19020
SINGLE CLAMP
(8) PROVIDED
19033
ANCHOR PLUG
(10) PROVIDED
DOUBLE CLAMP
(2) PROVIDED
PART 1
PART 2
3
SERVICE
To service the unit, loosen but do not remove (5) screws on one side
of guard. Slide clamps away from wire. Carefully rotate guard away
from light fixture to service.
STI-9880
62.75 in. (1593mm)
51 in. (1295mm)
STI-9881
98.25 in. (2495mm)
74.75 in. (1898mm)
LENGTH
MAXIMUM
MINIMUM
INSTALLATION INSTRUCTIONS
1. Align guard (part 1) over existing fluorescent light.
2. Mark (4) mounting holes. Set guard aside. Drill holes 1/4 in. (6.3mm) diameter and insert
anchors into ceiling. Install screws through clamps and into anchors. Do not tighten.
3. Position guard over light. Slide clamps onto top wire of guard and tighten screws.
4. Align guard (part 2) over existing fluorescent light guard. Have a minimum of 1 section of
wire overlapping.
5. Repeat steps 2 and 3.
6. Mark and drill holes for double clamp where part 1 and part 2 overlap. Insert anchors into
ceiling. Install screws through clamps and into anchors and tighten.
*
3.875 in
(98mm)
3.44 in (87mm)
4.625 in
(117mm)
113°
1.96 in
(50mm)
5.98 in
(152mm)
6.2 in
(157mm)
1.14 in
(29mm)
9.11 in
(231mm)
9.36 in
(237mm)
10.45 in
(265mm)