Cooling system and fans – Brocade ICX 6650 Hardware Installation Guide User Manual
Page 72
Environmental requirements (Continued)
TABLE 13
Condition
Acceptable during operation
Acceptable during non-operation
Shock
20 G, 6 ms, half-sine wave
33 G, 11 ms, half-sine wave, 3/eg Axis
Vibration
0.5 G sine, 0.4 gms random, 5-500 Hz
2.0 G sine, 1.1 gms random, 5-500 Hz
Airflow
Maximum - 90.1 cmh (53 cfm)Nominal - 59.5
cmh (35 cfm)
N/A
Heat dissipation
478 BTU/hr
N/A
Operating noise
46.7 dB
N/A
Cooling system and fans
The fans cool the CPU, main memory, and voltage regulators. For Brocade ICX 6650 switches, the
fans use either:
•
An exhaust airflow which moves air from front to back. Refer to the first figure below. Devices with
exhaust airflow are labeled with a green arrow with an “E.”
•
An intake airflow which moves air from back to front. Refer to the third figure below. Devices with
intake airflow are labeled with an orange arrow with an “I.”
Cooling system and fans
70
Brocade ICX 6650 Hardware Installation Guide
53-1003083-01