show tech-support cluster

9

show tech-support cluster

Collects and displays complete debugging information related to Multi-Chassis Trunking (MCT)
cluster configuration.

Syntax

show tech-support cluster

Parameters

None

Modes

Privileged EXEC mode

Command

Output

The show tech-support cluster command output includes the output of the show cluster and the
show cluster ccp peer detail commands. The show tech-support cluster command output displays
the following information:

Cluster configuration

Spanning Tree Protocol (STP), if configured

Rapid Spanning Tree Protocol (RSTP), if configured

Peer details

Cluster Communication Protocol (CCP)

Last reason for CCP down

Inter-Chassis Link (ICL)

MCT client

Transmission Control Protocol (TCP) connection

Examples

The following example displays sample output from the show tech-support cluster command.

Brocade# show tech-support cluster

Cluster Configuration information

cluster SX 3000 rbridge-id 2 session-vlan 3000 keep-alive-vlan 3001 icl

SX-MCT ethernet 1/7 peer 1.1.1.2 rbridge-id 3 icl SX-MCT deploy client

client-1 rbridge-id 100 client-interface ethernet 1/5

deploy !

Cluster SX 3000

============

Rbridge Id: 3, Session Vlan: 3000, Keep-Alive Vlan: 3001

Cluster State: Deploy

Client Isolation Mode: Loose

Member Vlan Range: 10 20 30

MCT Peer's Reachability using Keep-Alive Vlan: Peer Reachable

ICL Info:

---------

Name Port Trunk

SX-MCT 7/5 4

Peer Info:

----------

Peer IP: 10.20.152.21, Peer Rbridge Id: 2, ICL: SX-MCT

KeepAlive Interval: 10 , Hold Time: 90, Fast Failover

Active Vlan Range: 10 20 30

Last Reason for CCP Down: ICL VE interface down State: CCP Up (Up Time: 0 days:

5 hr:42 min:13 sec)