Tool requirements and parts list – Brocade Flush Mount Rack Kit Installation Procedure (Supporting VDX 6710-54, VDX 6720-24, VDX 6720-60, VDX 6730-32, VDX 6730-76, and VDX 6740) User Manual
Page 4

4 of 10
Flush Mount Rack Kit Installation Procedure
53-1002127-04
ATTENTION
Install the switch with the airflow aligned with any other switches in the rack. Some switches have airflow running from
port side to fan side and others have the opposite arrangement. Make sure that the airflow for all switches moves in
the same direction to maximize cooling.
Tool requirements and parts list
The following items are required to install a switch using the mid-mount rack kit:
•
Clamps or other means of temporarily supporting the switch in the rack.
•
Phillips #2 torque screwdriver
•
1/4-inch slotted blade torque screwdriver
ATTENTION
Use the screws specified for use with the switch. Longer screws can damage the switch.
Ensure that the items listed in
Table 2
and illustrated in
Figure 1
are included in the kit.
TABLE 2
Parts list
Description
Quantity
Brackets, front right and left
2
Brackets, rear right and left
1
Screw, 8-32 x 5/16-in., panhead Phillips
12
Screw, 10-32 x 5/8-in., panhead Phillips
8
Retainer nut, 10-32
8