Connecting the sfp+ module cable – Brocade FCoE Switch Module for IBM BladeCenter Installation and User’s Guide User Manual

Page 34

Advertising
background image

20

Brocade FCoE Switch Module for IBM BladeCenter: Installation and User Guide

Connecting the SFP+ module cable

ATTENTION

To avoid damage to the fiber optic cables, follow these guidelines:

•

Do not route the cable along a folding cable-management arm.

•

When you attach the cable to a device on slide rails, leave enough slack in the cable so that it
does not bend to a radius of less than 38 mm (1.5 in.) when the device is extended or become
pinched when the device is retracted.

•

Route the cable away from places where it can be snagged by other devices in the rack.

•

Do not overtighten the cable straps or bend the cables to a radius of less than 38 mm (1.5 in.).

•

Do not put excess weight on the cable at the connection point. Make sure that the cable is well
supported.

To connect the SFP+ module cable, complete the following steps:

1. Remove the protective caps from the end of the fiber optic cable.

FIGURE 9

Fiber optic cable cap

2. Gently slide the fiber optic cable into the SFP+ module until it clicks into place.

1

Fiber optic cable

2

Protective cap

1

2