Equipment status – Brocade Fabric OS Troubleshooting and Diagnostics Guide (Supporting Fabric OS v7.3.0) User Manual

Page 109

Advertising
background image

Fabric OS Troubleshooting and Diagnostics Guide

93

53-1003141-01

Equipment status

10

20: 6.3k 6.6k 0 0 0 0 0 0 7 0 0 1 2 0 0

21: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

22: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

23: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

24: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

25: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

26: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

27: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

28: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

29: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0

30: 664k 6.7k 0 0 0 0 0 0 6 0 0 1 2 0 0

31: 12 4 0 0 0 0 0 0 3 0 0 1 2 0 0

(output truncated)

The portErrShow command output provides one output line per port. Refer to

Table 19

for a

description of the error types.

Equipment status

You can display status for fans, power supplies, and temperature.

NOTE

The number of fans, power supplies, and temperature sensors depends on the switch type. For
detailed specifications on these components, refer to the switch hardware reference manual. The
specific output from the status commands varies depending on the switch type.

TABLE 19

Error summary description

Error type

Description

frames tx

Frames transmitted

frames rx

Frames received

enc in

Encoding errors inside frames

crc err

Frames with CRC errors

crc g_eof

CRC errors that occur on frames with good end-of-frame delimiters

too shrt

Frames shorter than minimum

too long

Frames longer than maximum

bad eof

Frames with bad end-of-frame delimiters

enc out

Encoding error outside of frames

disc c3

Class 3 frames discarded

link fail

Link failures (LF1 or LF2 states)

loss sync

Loss of synchronization

loss sig

Loss of signal

frjt

Frames rejected with F_RJT

fbsy

Frames busied with F_BSY

Advertising