Gathering additional information
7
Use the lsCfg –restore_slot_to_default command to correct the problem. Once the configuration
discrepancy has been fixed, you may use slotPowerOff followed by slotPowerOn to recover.
>lscfg –restore_slot_to_default 1
>slotpoweroff 1
>slotpoweron 1
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 SW BLADE 77 FC8-64 ENABLED
2 SW BLADE 97 FC16-32 ENABLED
3 SW BLADE 96 FC16-48 ENABLED
4 SW BLADE 96 FC16-48 ENABLED
5 CORE BLADE 98 CR16-8 ENABLED
6 CP BLADE 50 CP8 ENABLED
7 CP BLADE 50 CP8 ENABLED
8 CORE BLADE 98 CR16-8 ENABLED
9 SW BLADE 55 FC8-32 ENABLED
10 SW BLADE 96 FC16-48 ENABLED
11 AP BLADE 75 FX8-24 ENABLED
12 SW BLADE 97 FC16-32 ENABLED
Gathering additional information
For Virtual Fabrics-related issues, use the following guidelines to gather additional data for your
switch support provider:
•
Use the supportSave command.
•
If not sure about the problem area, use the supportSave command on all chassis and logical
switches in the fabric.
•
If you think it may be related to E_Port authentication, then use the supportSave -n command
on both switches or logical switches of the affected E_Port.