Physical port setting guidelines

It is recommended that you use the default settings listed in

Port class default settings

on page 67 for

most Port class areas. Consider the Port class to be a superset containing the E_Port, FOP_Port, and
FCU_Port subclasses. If you make a change to a default setting for an area in the Port class, it applies
to all of the subclasses. This is convenient if you have determined that changes you plan to make to the
default settings for the subclasses are the same for certain areas. In this case, you only need to make
the changes to the Port class. Note, however, that if you make a change to one of the subclasses, that
change overrides the Port class setting.

Port class default settings

Port class default settings

TABLE 16

Area

Description

Default threshold
settings

Default alarm
settings

Threshold
state

Cyclic
redundancy
check (CRC
with good
EOF (crc
g_eof)
markers)

Monitors the number of CRC errors. Unit: Errors

Time Base: minute

Low: 0

High: 1000

Buffer: 100

Below: 0

Above: 0

Informative

Out_of_range

Invalid
transmission
words (ITW)

Monitors the number of invalid
words transmitted.

Unit: Errors

Time Base: minute

Low: 0

High: 1000

Buffer: 100

Below: 0

Above: 0

Informative

Out_of_range

Class 3
discards
(C3TX_T0)

Class 3 discards frames due to
time-out or destination unreachable.

Unit: Errors

Time Base: minute

Low: 0

High: 2

Buffer: 0

Below: 0

Above: 0

Informative

Out_of_range

Link loss

Monitors the number of link failures. Unit: Errors

Time Base: minute

Low: 0

High: 500

Buffer: 50

Below: 0

Above: 0

Informative

Out_of_range

Signal loss

Monitors the number of signal loss
errors.

Unit: Errors

Time Base: minute

Low: 0

High: 5

Buffer: 0

Below: 0

Above: 0

Informative

Out_of_range