• interface mgmt 1: This interface is mgmt1 in the guest OS.
• interface ethernet 1: This interface is not visible to the guest OS.
• interface ethernet 2: This interface is not visible to the guest OS.
• interface ethernet 3: This interface is not visible to the guest OS.

The data interfaces in the Brocade Virtual ADX software are numbered in the order that the virtual
NICs are added. You must configure the data interfaces only through the Brocade Virtual ADX
interface commands. The following command on the Brocade Virtual ADX displays the state of the
interfaces.

Virtual ADX (config)#show interface brief

Port Link State Dupl Speed Trunk Tag Priori MAC Name

1 Up Forward Full 10G None No level0 000c.292f.4a21

2 Up Forward Full 10G None No level0 000c.292f.4a2b

3 Up Forward Full 10G None No level0 000c.292f.4a35

mgmt1 Up Forward Full 1G None No level0 000c.292f.4a17

You can add or remove data interfaces from the Brocade Virtual ADX. Refer to

Additional interfaces

on page 21 for information on adding and removing interfaces. The minimum and maximum
numbers of data interfaces are 1 and 8 respectively. A minimum of two virtual NICs must be assigned
to the Brocade Virtual ADX.

Typical deployment topologies

You can deploy the Brocade Virtual ADX on a single subnet or multiple subnets. You can also deploy
the Brocade Virtual ADX as a stand-alone appliance. You can deploy the Brocade Virtual ADX in In-
line and One-arm topologies. For detailed information, refer to Brocade Virtual ADX Server Load
Balancing Deployments
.

Tools supported on Virtual ADX

Brocade Virtual ADX supports the following cURL tool.

cURL

The cURL command line tool is for transferring data using URL syntax. For further information about
cURL, refer to

http://curl.haxx.se/

.

When 10 successive cURL transactions to an IP address are successful, the Brocade Virtual ADX can
initiate subsequent cURL sessions to the same IP address after waiting approximately two minutes.
However, the Brocade Virtual ADX can initiate cURL sessions for other IP addresses immediately.

NOTE
The Brocade Virtual ADX supports a maximum of 10 cURL sessions simultaneously.

You can run cURL from the Brocade Virtual ADX console. For example: