Davey POOL AND SPA GAS HEATERS User Manual

Page 15

Advertising
background image

Part No: 96131430D

15

Rev: 2

PROGRAMMING MODE

IMPORTANT!

Heater must be in AUTO mode before timer periods can be set. AUTO mode is selected by pressing the PROG button.

All time periods must be programmed, even if not required and must be set in the correct time sequence for the controller to
operate correctly in AUTO mode. Note: The programming operation can be exited at anytime by selecting the POWER button.

Example:

TIMER

PERIOD

START

TIME

If these time periods are set the

operation sequence will be as

follows:

Period1>Period2> Period4

Period 3 will be ignored

1 7:00am
2 9:00am
3 8:30pm
4 9:00pm

With the controller in the AUTO mode, switched “On” and displaying the current water temperature, press the PROG button for at
least 5 seconds to access the programming mode. The time of day will be displayed briefly prior to accessing programming mode.

1. Once the programming mode has been accessed SET and day of week selection will flash.

2. The first item to be programmed is the day of the week. Use the ▲or ▼buttons to scroll through the days of the week. Press

PROG

to lock in the day selection/s.

3. The start time of period 1 will then flash. Press the ▲or ▼buttons to adjust the start time. Press the PROG button to lock in the

start time.

4. Either POOL or SPA will now flash in the display indicating the mode selected. Use the MODE button to toggle between Pool

and Spa modes. Press the PROG button to lock in the selected mode.

5. The desired temperature for the selected mode must now be set for period 1. On first use the temperature will flash OFF. This

setting is used when the heater is not required to heat the water but the time setting is to be used for operating auxiliary
equipment. Use the ▲or ▼buttons to scroll through the temperature settings. The minimum set temperature is 18°C. Pressing
the ▼button when the temperature is at 18°C will select the OFF mode for period 1. Press PROG to lock in the temperature
selection.

6. The Auxiliary Output selection/s will now flash. Use the ▲or ▼buttons to scroll through the six (6) auxiliary selections.

Note:

Programming auxiliary equipment operation is only necessary if the Davey Equipment Interface Box (EIB) is installed and

auxiliary equipment has been connected.

7. To turn an auxiliary output “On” press the AUX button when the desired AUX item (1 to 6) is flashing. The word On is then

displayed above the auxiliary selection. Press the ▲button to move to the next available auxiliary output.

8. Once the desired selection/s have been made, press PROG to lock in the auxiliary output/s.

9. The display will now move to timer period 2 which may be programmed in the same manner.

Note:

All four timer periods must be programmed even if all temperature selections and auxiliary outputs are set to off or not

required. The program function will operate each timer period in the sequence 1 to 4.

10. The display will now return to its normal position.

CHILD LOCK FUNCTION

The child lock function will render all 6 controller switches inactive.

1. To activate the child lock function press and hold both the ▲and ▼buttons for 10 seconds. The lock symbol will be displayed.

2. To cancel the child lock function press and hold the ▲and ▼buttons for 10 seconds.

Advertising