24v ac actuator connection terminal strip – Davey POOL AND SPA GAS HEATERS User Manual

Page 18

Advertising
background image

Part No: 96131430D

18

Rev: 2

WARNING! Ensure that each valve operated by the actuator is not able to pass through a position that will close supply from the
pump and result in pressurisation of the pool system. Failure to observe this may result in severe damage to the pool system
piping, equipment and or cause personal injury and property damage. Correct installation is the responsibility of the system
installer.

WARNING! Do not attempt to connect 240V equipment to the 24VAC relay.

Note:

For models, 131, 127 and 167 a 24VAC relay can be added to enable operation of actuators as previously described. This

component must be installed and connected by a licensed electrician.

FLUE DILUTION KIT & EXTERNAL CONTROLS

Models 200, 280, 350, 430 Only
These models include a second terminal strip, which enables connection of the optional Dilution Fan Kit (for Indoor installations
only) and an external thermostat control (see figure below).

The Dilution Fan Kit is installed as shown in the wiring diagram supplied with the kit, between terminals A1 and A2, after removing
the corresponding link.

To install an external thermostat control, remove the link between terminal 1 and 2 and connect the thermostat between the
terminals (voltage-free, normally-closed contacts only).

External Controls

Terminal Strip

24V AC

Actuator Connection

Terminal Strip

No

rm

al

ly

Cl

os

ed

S

w

itched

C

lo

se

d

N

eut

ra

l

Neu

tr

al

S

w

itched

C

lo

se

d

N

or

m

al

ly

C

los

ed

Re

d

Wh

ite

Bl

ac

k

Wh

ite

Re

d

Advertising