7.

MISC OPTIONS

- - - -

(SUBMENU)

(

)

(

)

(ESC)

(

)

(

)

- - - -

MISC.

OPTIONS

Push 7

1. KEY CLICKS
2. MAIN DISPLAY

5. PANEL & POOL LIGHT SYNC*
*Only available if a SPVCL is
fitted to pool

3. PANEL LIGHT COLOUR
4. PANEL LIGHT INTENSITY

Scroll to SET

(CHANGE)

(

)

(

)

1. KEY

CLICKS

1. SET TEMP
2. USER TIMER
3. CLOCK
4. USER ALARM
5. SLEEP TIMES
6. MAINT TIMERS

8. ADV. OPTIONS
9. LD. DEFAULTS

7. MISC OPTIONS

Page 24

- - - -

Select MAIN menu then push UP button 7 times

7.8 Miscellaneous Options Submenu

The miscellaneous options menu contains convenience options that primarily allow you to customise the look of the
poolside touch panel. None of the options have any effect upon the basic spa control functions such as pump
operation or heating.

7.8.1 Key Clicks (on/off)

By default the touch pad will beep whenever a button is pressed, however key clicks (beeps) may be turned on and off
as desired using the procedure below:

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the KEY CLICKS menu item
3) Press the SCROLL button
4) Use the UP and DOWN buttons to toggle between on and off
5) Press SCROLL button to set

Note: Disabling key clicks will not silence user timer beeps etc.

Up

Down

Page 9

3.6 24Hr Circulation Pump On/Off

If a circulation pump has been fitted the spa manufacturer may have assigned an on/off button on the touch pad to
turn the circulation pump on and off. If a button has been assigned follow the instructions below.
-To switch circulation pump off push the assigned button.
-To switch the circulation pump on push the assigned button.

5 Spa Power Variable Speed Blower (SPVSB)

Note:
If the circulation pump is switched off it will be reactivated after 25 minutes of touch pad inactivity.

The Air Button controls a Spa Power Variable-Speed Blower (if fitted). It is used to turn the blower on/off and select
different operating modes.

Four pushes of the air button cycle the blower as follows:

5.1 Adjustable Speed Mode (SPVSB)

In the adjustable speed mode the UP and DOWN buttons are used to set the blower to one of 9 different speeds.
On the first press of UP or DOWN the LCD will display “BLOWER SPEED” along with a bar graph showing the
current speed setting. While viewing this display you may press the UP and DOWN button to adjust the speed as
required. Hold down either button for automatic key press repeat. This setting is saved and will be automatically
restored next time you select the adjustable speed mode.

Notes:
1) The UP and DOWN buttons are shared with Light Level, Light Mode, SPVSB speed and the menu system.

When not within the menu system the actual use of the UP and DOWN buttons depends on which of the three
function buttons was pressed last - Light Level, Light Mode or Air.

4 Auxillary On/Off (pump, blower, light)

Two pushes of the Auxilary button cycles the outlet as follows:

Push 1

(Aux On)

Push 2

(Aux Off)

LCD displays “Aux Off”, button LED off.

LCD displays “Aux On”, button LED green.

Notes:
1) If Aux is left on, this oulett will automatically switch off after 25 minutes.
2) If the heater element is on, running this outlet may cause the heater to load shed and switch off. If this occurs

the heater will come back on approximately 5 seconds after the pump is deselected.

Push 1

(Blower On)

Push 2

(Blower Ramping)

Push 3

(Blower Speed)

Push 4

(Blower Off)

LCD Displays “BLOWER ON HIGH”, Blower on
full speed

LCD Displays “BLOWER OFF”, (Default State)

LCD Displays “BLOWER SPEED” and bar graph
Showing actual speed setting, Blower on adjustable
speed (see below)

LCD Displays “BLOWER RAMPING”, speed oscillating

Advertising